ECM TO PSC MOTOR REPLACEMENT/ CONVERSION WIRING pt 4
wiring up the psc motor after converting or replacing from ecm motor using relay #d2dnyac
Переглядів: 252
Відео
NAMING ALL COMPONENTS INSIDE TRANE COMMERCIAL HEATING FURNACE
Переглядів 684Місяць тому
NAMING ALL COMPONENTS INSIDE TRANE COMMERCIAL HEATING FURNACE
ZIEHL ABEGG EC BLUE FAN MOTOR | TROUBLESHOOT AND TEST
Переглядів 2,1 тис.2 місяці тому
ZIEHL ABEGG EC BLUE FAN MOTOR | TROUBLESHOOT AND TEST
ECM TO PSC BLOWER MOTOR CONVERSION
Переглядів 3,3 тис.2 місяці тому
ECM TO PSC BLOWER MOTOR CONVERSION
DIY HVAC MAINTENANCE TIP REPLACE your AiR FILTERS
Переглядів 3273 місяці тому
DIY HVAC MAINTENANCE TIP REPLACE your AiR FILTERS
COOPER HUNTER MINI SPLIT ERROR CODE F5 TROUBLESHOOT
Переглядів 4413 місяці тому
COOPER HUNTER MINI SPLIT ERROR CODE F5 TROUBLESHOOT
HVAC TROUBLESHOOTING | CHECKING SUPERHEAT & SUBCOOLING
Переглядів 5373 місяці тому
HVAC TROUBLESHOOTING | CHECKING SUPERHEAT & SUBCOOLING
HVAC TROUBLESHOOTING | HVAC SERVICE | COMMERCIAL HVAC
Переглядів 1,4 тис.4 місяці тому
HVAC TROUBLESHOOTING | HVAC SERVICE | COMMERCIAL HVAC
HVAC TROUBLESHOOTING | WATER FURNACE GEOTHERMAL | pt.2
Переглядів 3564 місяці тому
HVAC TROUBLESHOOTING | WATER FURNACE GEOTHERMAL | pt.2
EASILY RECOVER ANY REFRIGERANT AND KEEPING IT REUSABLE
Переглядів 1 тис.4 місяці тому
EASILY RECOVER ANY REFRIGERANT AND KEEPING IT REUSABLE
SINGLE PHASE COMPRESSOR AND MOTOR WIRING THEORY
Переглядів 4085 місяців тому
SINGLE PHASE COMPRESSOR AND MOTOR WIRING THEORY
THE MOST FUTURISTIC RTU EVER | COMMERCIAL HVAC
Переглядів 6405 місяців тому
THE MOST FUTURISTIC RTU EVER | COMMERCIAL HVAC
COMMERCIAL HVAC LIEBERT/ VERTIV MAINTENANCE REPLACING FAN BELT
Переглядів 3805 місяців тому
COMMERCIAL HVAC LIEBERT/ VERTIV MAINTENANCE REPLACING FAN BELT
TROUBLESHOOTING WATER FURNACE GEOTHERMAL HEAT PUMP
Переглядів 1,2 тис.5 місяців тому
TROUBLESHOOTING WATER FURNACE GEOTHERMAL HEAT PUMP
EASILY LIGHT HOT WATER HEATER PILOT LIGHT
Переглядів 4676 місяців тому
EASILY LIGHT HOT WATER HEATER PILOT LIGHT
LET’S TAKE A LOOK AT THIS FUTURISTIC RTU
Переглядів 7556 місяців тому
LET’S TAKE A LOOK AT THIS FUTURISTIC RTU
HOW TO LIGHT PILOT LIGHT HEATING FURNACE \\ BOILER
Переглядів 1056 місяців тому
HOW TO LIGHT PILOT LIGHT HEATING FURNACE \\ BOILER
HVAC CONTROLS | RELIATEL MICRO PROCESSOR CONTROLS
Переглядів 4016 місяців тому
HVAC CONTROLS | RELIATEL MICRO PROCESSOR CONTROLS
TROUBLESHOOT VRV | VRF | SYSTEM | LGMV SERVICE TOOL
Переглядів 2,4 тис.6 місяців тому
TROUBLESHOOT VRV | VRF | SYSTEM | LGMV SERVICE TOOL
HVAC TROUBLESHOOTING | COMPRESSOR LOCKED
Переглядів 8637 місяців тому
HVAC TROUBLESHOOTING | COMPRESSOR LOCKED
HVAC TROUBLESHOOTING MEGGER TESTED THE COMPRESSOR
Переглядів 1,1 тис.8 місяців тому
HVAC TROUBLESHOOTING MEGGER TESTED THE COMPRESSOR
Really helps to use your alligator leads. Just put your alligator leads on the common and run or common and start and keep water in that thing down until it rings out.
If you have a box of any kind like that on a wall if the box is low to the ground hatch opens downwards so you can easier see Inside the box without having to get all the way down. And vice versa for the door opening upwards if it’s at or above eye level.
thanks these fitting really help
I have a intellipak with a vsc drive on circuit 2. This drive is always faulting on single phase u, v, and w. Any advise?
How to know if the motor protector has gone bad? Any idea?
If the switch contacts is opened all the time no matter if compressor is cool or not
@@D2DNYACThe switch contact you meant is it the low pressure and high pressure switch ? So it's from the M1 and M2 ?
You have filtre
Impressive ma dude. We can use you in NYC,do you do light R as well? If looking let me know
Thank you for stopping by
Ya Mon you are a great tech. Excellent explanation bro! Bless!!!!
Thank you for stopping by
What if after my pilot light goes to blue, I switch nob to A then the blue light turns to red...??
Possible bad thermocouple
So delta P is test result?
Is the deviation of difference plus or minus between starting test pressures and the current
What is delta P
A delta P of minus 5 psig means that your system lost 5 psig since the test started
What watch is that? Looks dope! I like the bracelet! I have a 26 Jewel Mechanical Wind Up Watch with a similar looking bracelet. Very reliable watch.
Citizen eco drive navihawk
Good job Sir! Those greedy ass holes need to be sued into oblivion. A $200 Chinese PSC is simpler and more reliable than a $1200 piece of junk ECM. I will never buy an AC unit or a Furnace with that ECM junk in it. That is why I like York 13 Seer systems. Simple, affordable and not the worst reliability, spare parts are usually in stock.
The most immediate benefits of these ecm motor is quiet starting and stopping beside that it's completely BS on an individual basis
I love the title LOL.
Thanks for watching
Some relay doesn’t have any sign on them. How to know where to connect the low voltage (the 24v)?
There’s always some form of marking , however as a last resource use your ohm meter!! Look out for a video on that!
i found a re manufactured motor for 325.00 at united hvac motors. got it next day but its the next county over. replaced it two years ago.lightening damage most likely.
This solution would have been even le$$
i found your video while looking how to repair blower motor internal capacitor because it was not in air handler only to learn i have an ecm motor. 300.00 for ecm controller, whole motor assembly starting at 650.00.this looks like the way to go swapping to brush motor with cap and relay.do you think the electric bill will go up much? thanks for the info.
also when i put reman 300.00 motor i did not buy the offered surge protector witch i will be adding. do you think these surge protectors work.it was a bad thunderstorm in fla when the compressor cap and blower motor failed .
As an individual user these ECM motors are more luxury than energy saving. If you were to combine 100 of them then the savings would start to make a little sense
If you leave it a little loose at the schrader valve you can wiggle it and pops out easily some times there a pain to get out when they have been there for a long time i work in super market referigeration some of those have been there for 10 years or more
💪🫡
Get the fieldpiece one It has sight glass
Really
Sabes como calibrar pantalla?
No habla Español
How I can calibrate the touch screen. I turned off the unit and power on... but I can't find the menu, when is starting up.... Thank 😅
Bro get to the point. We obviously know that compressors have oil.
Thanks for watching
I appreciate your video and am looking for more. Would you please make a detailed tutorial on connecting and purging your hoses with the testo four port manifold?
Okay
Hey yardie help me fix my ac it’s a Lennox
We can try
Love this video really helpfull and deatailed
Thanks for watching
Excellent diagnostics
Thanks for watching
Wow!
Right
So lower speed can be wired with another relay controlled by C and W from thermostat ?…
👍 yes sir 👏
Well done!
Thank you for stopping by
I can still see the bubbles 😂
🤣🤣 I found out from someone in the comments that nylog works well too , front seat it then apply then back seat again 💪💪💪
thanks
Thanks for watching
TGANKS
💪💪
Who did the hack job on trying to braze the suction line😂
🤣🤣🤷♂️
Why you keep moving your camera around.
So you keep following 😂 thanks for watching
please change the title of the video. you are not converting ecm motor to psc motor. you are replacing from ecm to psc.
Thanks 🙏
My service tech said he is not allowed to do that if the valve is outside the unit.
Well 🤷♂️
You’re professional bro.
Thanks for watching
Thank you buddy i’ learn something new today. Thank you.
Thank you for stopping by
Thank you so much you helped out me and my family in this heatwave.
Thank you for stopping by
I may be a little late but im about to make this repair and i have a question. Do you take out the schrader valve from the original access port beofre you put the tee on or do you have a fitting in the female of the tee to press the valve in?
The latter!
Why did you do this? Was the motor not available?
Not available
Thank you so much for the detailed info. It was very helpful!❤
Thanks for watching
Pressure gauge on an inverter compressor is hilarious
How come u didn’t use an adjustable mechanical switch? I’m not a fan of those capsule switches.
6 is one 1/2 dozen the other same difference , if you can't find what you want then adjustable switch to get it
wrong technician to be there. lol
😂😂
I can make the high pressure goes really high ? I’m having a problem with a system with a pressure of 320+ but bubbles in sight glass
What refrigerant?
Yay😅
Thanks for watching
Air torch take too long for me
Spoken like a true oxygen and Acetylene guy
carrier unit?
A Trane brand Oxbox
Make sure you have your fire watch
Yes sure